Field controls 02722701 control draft 6 inch for oil or coal residential and commercial 6rc.
Miller roof jack assembly.
Outside pipe is 8 3 4 which fits over about an 8 1 2 pipe on the furnace.
2 connect roof jack assembly to the furnace.
Not in stock or as low as.
Connect roof jack assembly to furnace.
Redesigned all weather crown assembly helps minimize pilot light blow outs.
Add to cart 0 reviews compare.
Redesigned all weather crown assembly helps minimize pilot light blow outs factory replacement item easy installation instruction included fits miller intertherm broan furnace with model s that start with mi mbha mgba mgbb mgha mghb mmba mmbb mmha mmhb msba msbb msha mshb the 903656 roof jack cap is a redesigned all weather crown assembly that helps minimize pilot light blow outs.
Srj 1 standard roof jack 12 all cmf w 12 or less roof cavity 104060000.
It is adjustable from 27 to 47 when measured from the roof not ceiling to the top of the furnace.
Extension joints must be visible below ceiling.
Installing the roof jack 1.
Screw a 10 interior extension kit is available to extend the roof jack connection pipes.
Used on the above roof jacks and on roof jacks found on models m1 mbha mgba mgbb mgha mghb mmba mmbb mmha mmhb msba msbb msha mshb.
Commodity copper fittings 3490 elbow 90deg 3 4 copper 607.
The nordyne 903656 roof jack cap is a redesigned all weather crown assembly that helps minimize pilot light blow outs.
35 to 63 telescoping and adjustable roof jack 4 12 pitch for slope roofs 170 00.
Apply caulking compound on underside of roof flashing to form a continuous strip at least 3 8 wide around the underside of the perimeter of the flashing see figure 20 or figure 21 page 13.
238354 186 59 srj 3 standard roof jack 36.
Roof roof flashing roof jack assembly secure with appropriate fasteners furnace secure with s m.
Buy roof jack assembly 25 to 36 cmf series oil and gas furnace srj3.
Fits miller intertherm nordyne and broan furnace model numbers starting with mi mbha mgba mgbb mgha mghb mmba mmbb mmha mmhb msba msbb msha and mshb.
The outside pipe is 8 3 8 which fits over about an 8 1 4 pipe on the furnace.
9 3 4 diameter 20 13 1 4 10 rear wall of alcove 3.
This roof jack has an all weather crownfor a 3 10 or steeper roof slope.
51 to 95 telescoping and adjustable roof jack 4 12 pitch for slope roofs 264 99.
Not in stock or as low as.
Installation instructions are included.
Insert telescoping roof jack assembly through the opening cut on the roof.
Miller furnace 103947002 vent pipe 28.